Company & product scope
Power, oil-immersed, dry-type and special-purpose transformers.
Legal entity: 江苏亚威变压器有限公司
English display name is provided for navigation; the legal entity above identifies this record.
What you can compare in this record
These counts describe the documentation available here, not the manufacturer’s complete range or a certification result.
Prepare a precise request
- For oil-immersed proposals, specify the insulating liquid, installation and containment requirements, tap arrangement and loss guarantees.
- For dry-type proposals, request the insulation system, enclosure, ventilation requirements and the capacity available under each cooling mode.
- For power-transformer proposals, define each winding rating, tap duty, transport limits and the project test schedule.
- For special-purpose proposals, describe the actual duty, connection interface and any application-specific approval requirements.
Ask Jiangsu Yawei Transformer to identify the exact model and explain any differences between its catalogue and your project specification. Keep unresolved fields out of numerical comparisons.
Published sources supporting the product records
Documented products
Yawei 110 kV class · 8000 kVA catalogue configuration
110 kV series / 8000 kVA catalogue row
Yawei 110 kV class · 10000 kVA catalogue configuration
110 kV series / 10000 kVA catalogue row
Yawei 110 kV class · 6300 kVA catalogue configuration
110 kV series / 6300 kVA catalogue row
Yawei 35 kV renewable-energy oil-immersed series
35 kV renewable-energy catalogue series
Transformer categories
Rated capacity & no-load loss
| Model | Rated kVA | No-load loss (kW) | Source |
|---|---|---|---|
| Yawei 110 kV class · 8000 kVA catalogue configuration | 8000 | 4.9 | www.ywtransformer.com · Manufacturer-published |
| Yawei 110 kV class · 10000 kVA catalogue configuration | 10000 | 5.8 | www.ywtransformer.com · Manufacturer-published |
| Yawei 110 kV class · 6300 kVA catalogue configuration | 6300 | 4.1 | www.ywtransformer.com · Manufacturer-published |
Compare the same rated capacity, voltage, frequency and test conditions. A range does not guarantee every combination is available.
Technical evidence
110 kV catalogue capacity / loss table
Source checked on 2026-09-22. Catalogue rows: 6300 kVA / 4.1 kW; 8000 kVA / 4.9 kW; 10000 kVA / 5.8 kW no-load loss. These are manufacturer-published values, not independent test results. Reference temperature for load loss/impedance is not stated; these values are excluded from corresponding technical filters.
Open source document →Source: www.ywtransformer.com · 2026-09-22
Documents have not yet been independently reviewed. Company product descriptions are not substitutes for model-specific test evidence.
- Model & capacity
- Not independently checked
- Voltage ratio & frequency
- Not independently checked
- Cooling & insulation
- Not independently checked
- Winding & core materials
- Not independently checked
- No-load loss (kW)
- Not independently checked
- Load loss (kW) & reference temperature
- Not independently checked
- Impedance (%) & reference temperature
- Not independently checked
- Type test report: model, issuer, report number & date
- Not independently checked