Dalian Xinguang Transformer Manufacturing logo

MANUFACTURER PROFILE

Dalian Xinguang Transformer Manufacturing

Cast-resin and non-encapsulated dry-type routes alongside sealed-oil distribution transformers.

Discuss your project

Dalian Xinguang publishes a distribution-transformer catalogue covering epoxy cast-resin, non-encapsulated dry-type, sealed-oil and amorphous-core equipment. Its published contact address is in Zhuanghe, Dalian, Liaoning. For buyers comparing indoor distribution equipment, the useful distinction is between its SCB cast-resin route and its SGB non-encapsulated route. The archived SCB catalogue also contains rated-capacity, loss and impedance tables, allowing a more specific discussion than a general claim of “low loss.”

Chinese entity
大连新光变压器制造有限公司
Published location
No. 8 Yongxing Street, Zhuanghe, Dalian
Dry-type constructions
SCB cast-resin and SGB non-encapsulated
Oil-filled index
10 kV sealed-oil; 35 kV S11; SH15-M amorphous
Technical references
Dated manufacturer catalogue; exact offer conditions required
01

Start with the construction route

Scroll sideways to compare all columns.

Published routeCatalogue identificationBuyer decision
Epoxy cast-resin dry-typeSCB10(11)Indoor layout, cooling and temperature protection
Non-encapsulated dry-typeSGB10(11), described as H-classConstruction and insulation system required by the project
Sealed-oil distributionS9-M, S11-M, S13-M; 10 kV index entriesLiquid containment, installation and a current loss schedule
Higher distribution voltageS11; 35 kV index entryRequired insulation and voltage combination
Amorphous-core oil-filledSH15-MGuaranteed no-load loss at the specified rating

The manufacturer's product index lists SCB10(11) epoxy-resin dry-type transformers separately from SGB10(11) H-class non-encapsulated dry-type transformers. These are distinct product entries. An inquiry should identify which construction is required, rather than use “dry-type transformer” as the entire specification.

The oil-filled index includes S9-M, S11-M and S13-M sealed 10 kV families, an S11 35 kV entry, and SH15-M amorphous-core oil-filled equipment. Those catalogue names describe the published range; they do not establish today's applicable efficiency class or the losses of an individual offered unit. Specify the actual rating, winding material and guaranteed loss schedule when requesting a quotation.

References: [1]

02

What the cast-resin manufacturing description actually covers

Xinguang's SCB page describes segmented cylindrical high-voltage coils, with axial cooling passages on larger coils. It says the coils undergo vacuum drying before resin casting, with casting and curing carried out according to a programmed process curve. The low-voltage winding is described as foil construction with resin-sealed ends. These details give a buyer concrete topics for a technical review: winding construction, casting process, cooling passages and end protection.

The same page describes a 45-degree step-lap silicon-steel core and a resin surface-sealing process. The manufacturer associates those arrangements with vibration and loss control. They are descriptions of its published design approach, rather than measurements of every transformer leaving the factory. A procurement drawing and the inspection records for the offered design remain the documents that connect construction to delivered performance.

The process text and technical block use different insulation-class descriptions. A buyer should therefore ask for the insulation system and temperature-rise guarantee of the selected design in writing. Carrying one class label from a general catalogue into every model would conceal a material specification question.

References: [2]

03

Two 500 kVA loss schedules, kept with their conditions

Scroll sideways to compare all columns.

Archived catalogue rowRated capacityNo-load lossLoad loss at 120°CImpedance
SC(B)10500 kVA1.160 kW4.879 kW4%
SC(B)11500 kVA1.050 kW4.640 kW4%

The archived manufacturer page contains separate SC(B)10 and SC(B)11 technical tables. The following rows reproduce the two 500 kVA entries after conversion from watts to kilowatts. Load loss is explicitly headed 120°C in the original tables; impedance belongs to the 4% group in their merged cells. The table's voltage options include several primary voltages and a 0.4 kV secondary, so the exact selected primary voltage must be stated in the offer.

These are manufacturer-published catalogue figures from the original page saved on 23 September 2026. They are useful reference points for a request, rather than a current quotation or an acceptance-test result. Ask the supplier to return the guaranteed no-load loss, load loss at the agreed reference temperature, impedance tolerance and applicable loss evaluation method for the exact winding material and voltage combination being offered.

The original tables also contain two 630 kVA rows with different impedances. That is why capacity alone is insufficient for a fair comparison: a buyer must match the impedance design as well as capacity and temperature. We have kept the two 500 kVA rows above together because their stated comparison conditions align, instead of combining values from unlike rows.

References: [2]

04

Cooling, enclosure and the transformer room

The SCB technical description lists natural-air and forced-air cooling, AN and AF. It also describes three-phase winding-temperature monitoring with fan control, alarm and trip functions. An indoor buyer should specify the control interfaces, sensor arrangement and whether fans are required, rather than assume that every catalogue illustration includes the same accessories.

Published enclosure options include IP00, IP20 and IP23. The catalogue's standard-use description includes an indoor installation, ambient temperature no higher than 40°C and altitude no higher than 1,000 metres. A room with restricted ventilation, higher altitude or a different ambient profile needs a specific proposal. An enclosure choice must be considered together with airflow, access for maintenance and the required continuous rating.

For a replacement unit, send a room plan showing incoming and outgoing cable positions, door openings, clearances and the intended foundation. For a new room, obtain the manufacturer's heat-release figures and general-arrangement drawing before finalising ventilation and switchgear spacing. These are procurement recommendations drawn from the installation conditions, not claims about a completed Xinguang project.

References: [2]

05

Zhuanghe identity and the historical record

The catalogue contact block names 大连新光变压器制造有限公司 and gives No. 8 Yongxing Street, Zhuanghe, Dalian. A Zhuanghe municipal-government notice, document 庄政办发〔2008〕43号, also lists the same Chinese company name in an administrative-jurisdiction attachment under Xinhua subdistrict. The notice was issued on 15 June 2008 and published on 20 June 2008.

That record establishes a dated local reference for the enterprise name. It does not establish a present manufacturing licence, current ownership structure or export approval. When preparing a contract, use the legal name and current address supplied in the commercial documents, and make sure the drawing, quotation and test-report entity agree with the intended contracting manufacturer.

References: [1] [3]

06

Move from a catalogue entry to an orderable design

Xinguang's archived technical page cites older editions of transformer standards. The purchase specification should name the editions and requirements actually applicable to the destination project. A series designation such as SCB10 or SCB11 should not replace a current efficiency requirement, an agreed partial-discharge criterion or the complete routine-test schedule.

A useful first inquiry combines the construction route, continuous kVA, primary and secondary voltages, vector group, frequency, tap range and impedance with the installation envelope. Add copper or aluminium explicitly, then ask for loss guarantees under the same rating and reference-temperature conditions used for competing offers. If forced cooling is proposed, distinguish the natural-air continuous rating from the fan-assisted rating.

For the technical return, request a general-arrangement drawing, terminal layout, mass, enclosure and cooling configuration, loss schedule and test plan. Keep delivery milestones and acceptance documents tied to that selected design. This turns the two distinct dry-type routes and the published catalogue tables into a practical supplier discussion, without treating an archived series page as a finished project specification.

References: [2]

Explore the product detail

Use each product record to review the published configuration, then request the proposed specification for your project.

Documented capacity & loss values

Compare the same rating, voltage, frequency and test conditions.

Product documents

A project brief the factory can respond to

Use this list to prepare your requirements. Checking an item only marks your preparation on this page.

0 of 6 items prepared

Prepare an RFQ for XINGUANG

Questions buyers ask

Does Xinguang list more than one dry-type construction?

Yes. Its product index separates SCB10(11) epoxy cast-resin equipment from SGB10(11) H-class non-encapsulated equipment. Name the required construction in the inquiry and request the selected design's insulation and temperature-rise specification.

Can I compare the published 500 kVA losses directly?

The two archived rows above share the stated 500 kVA rating, 4% impedance and 120°C load-loss reference. Their figures are catalogue references. Confirm the exact voltage, winding material, tolerance and current guarantee before comparing a commercial offer.

Is the 2008 municipal record a product certification?

No. It is a historical administrative notice listing the enterprise name. Product conformity and order acceptance depend on the applicable documents and tests for the selected equipment.

What should an indoor replacement inquiry include?

Include the room plan, access dimensions, cable positions, continuous rating, ambient and altitude, enclosure requirement and control interfaces. Specify whether the installation requires natural-air operation, fan assistance or both ratings.

Sources

3 sources · checked 8 October 2026

Prepared by PowerTransformerB2B. Checked 8 October 2026. The sources below identify the published company information and any dated public records used for this profile.

Company catalogues describe product families and options. Before you order, ask the manufacturer for the type-test report and acceptance documents for your exact model and rating.

  1. [1] Product index and published contact identityDalian Xinguang · Manufacturer original archive
  2. [2] SCB10(11) constructions and original loss tablesDalian Xinguang · Manufacturer original archive
  3. [3] 2008 administrative-jurisdiction notice, 庄政办发〔2008〕43号Zhuanghe municipal government · Government original notice