Dalian Xinguang Transformer Manufacturing

Dalian, Liaoning

Company & product scope

Oil-immersed, cast-resin dry-type and amorphous transformers.

Legal entity: 大连新光变压器制造有限公司

English display name is provided for navigation; the legal entity above identifies this record.

What you can compare in this record

4Catalogue records
3Capacity / no-load loss pairs
3Load-loss records with reference temperature

These counts describe the documentation available here, not the manufacturer’s complete range or a certification result.

Prepare a precise request

  • For oil-immersed proposals, specify the insulating liquid, installation and containment requirements, tap arrangement and loss guarantees.
  • For dry-type proposals, request the insulation system, enclosure, ventilation requirements and the capacity available under each cooling mode.

Ask Dalian Xinguang Transformer Manufacturing to identify the exact model and explain any differences between its catalogue and your project specification. Keep unresolved fields out of numerical comparisons.

Published sources supporting the product records

How to check report coverage → · How to compare losses →

Documented products

Xinguang SCB10 / SCB11 cast-resin series

SCB10 / SCB11

Xinguang SC(B)10 800 kVA catalogue row

SC(B)10 / 800 kVA

Xinguang SC(B)10 1250 kVA catalogue row

SC(B)10 / 1250 kVA

Xinguang SC(B)10 1000 kVA catalogue row

SC(B)10 / 1000 kVA

Transformer categories

Rated capacity & no-load loss

ModelRated kVANo-load loss (kW)Source
Xinguang SC(B)10 800 kVA catalogue row8001.52www.dlxgbyq.com · Manufacturer-published
Xinguang SC(B)10 1250 kVA catalogue row12502.088www.dlxgbyq.com · Manufacturer-published
Xinguang SC(B)10 1000 kVA catalogue row10001.768www.dlxgbyq.com · Manufacturer-published

Compare the same rated capacity, voltage, frequency and test conditions. A range does not guarantee every combination is available.

Technical evidence

Manufacturer catalogue source review

Checked 2026-09-23 against the manufacturer page. Manufacturer table lists 6/6.3/6.6/10/10.5/11 kV primary options. Load loss is at 120 C. Impedance reference temperature is not stated, so no condition-matched impedance value is imported. Historical catalogue, current availability unconfirmed. This is a published-source record, not independent test verification.

Open source document →
Source: www.dlxgbyq.com · 2026-09-23

Manufacturer catalogue source review

Checked 2026-09-23 against the manufacturer page. Manufacturer table lists 6/6.3/6.6/10/10.5/11 kV primary options. Load loss is at 120 C. Impedance reference temperature is not stated, so no condition-matched impedance value is imported. Historical catalogue, current availability unconfirmed. This is a published-source record, not independent test verification.

Open source document →
Source: www.dlxgbyq.com · 2026-09-23

Manufacturer catalogue source review

Checked 2026-09-23 against the manufacturer page. Manufacturer table lists 6/6.3/6.6/10/10.5/11 kV primary options. Load loss is at 120 C. Impedance reference temperature is not stated, so no condition-matched impedance value is imported. Historical catalogue, current availability unconfirmed. This is a published-source record, not independent test verification.

Open source document →
Source: www.dlxgbyq.com · 2026-09-23

Manufacturer catalogue source review

Checked 2026-09-23 against the manufacturer page. Introduction states 80–2500 kVA; the separate SC(B)10 table also includes smaller ratings. Keep each row separate. Source references historical standards; confirm current design and compliance. This is a published-source record, not independent test verification.

Open source document →
Source: www.dlxgbyq.com · 2026-09-23

Documents have not yet been independently reviewed. Company product descriptions are not substitutes for model-specific test evidence.

Model & capacity
Not independently checked
Voltage ratio & frequency
Not independently checked
Cooling & insulation
Not independently checked
Winding & core materials
Not independently checked
No-load loss (kW)
Not independently checked
Load loss (kW) & reference temperature
Not independently checked
Impedance (%) & reference temperature
Not independently checked
Type test report: model, issuer, report number & date
Not independently checked