SCB 10 kV dry-type transformer series

Model specifications, source documentation and manufacturer contact.

Indoor cast-resin product series · select one rating before comparison

Daqo's 10 kV SCB listing defines an indoor cast-resin family, not one transformer with every published option. Use the range to start a 10/0.4 kV enquiry, then pin down the model, capacity, connection, cooling and guaranteed losses on a single returned rating sheet.

Discuss this configuration Nanjing Daqo Transformer logoNanjing Daqo Transformer →
SCB12 / SCB14 / SCB18 manufacturer catalogue image

CATALOGUE IDENTITY

SCB12 / SCB14 / SCB18
Series models
SCB12 / SCB14 / SCB18
Published range
30–5,000 kVA
Standard voltage listing
10 / 0.4 kV
Installation
Indoor
01

Make one rating sheet from the series options

A capacity range tells you where to start asking. It does not fix the losses, impedance or installation package for a particular capacity.

Ask the supplier to return one consolidated sheet against your project diagram. Capacity, connection, impedance and insulation choices should not be combined by picking the most attractive value from each range. The structured product record keeps the 4–10% figure in its condition note rather than pretending it is the impedance of a particular unit.

A family photograph and the SCB name identify the product category. They do not establish the exact enclosure, winding materials, dimensions, mass or accessories that will be delivered.

Scroll this table to read every column →

Published series itemWhat the listing establishesWhat the offer must identify
SCB12, SCB14, SCB18Named models within the SCB familyThe selected model and current design revision.
30–5,000 kVA; 10/0.4 kVSeries capacity range and listed voltage ratioOne capacity, frequency, taps and actual rated voltages.
Dyn11 or Yyn0; 4–10% impedanceConnection options and a series-level impedance rangeOne connection group and impedance with the agreed rating and conditions.
Class F or HPublished insulation optionsThe delivered insulation system and its temperature-rise limits.

Source notes: [D1] [D2]

02

Ask what the forced-air rating actually covers

The manufacturer's overview advertises operation at 150% of rated load under forced-air cooling. It does not provide a model-specific duration, ambient condition or complete temperature-rise record alongside that claim. Do not convert it into a continuous 1.5-times-capacity guarantee for your chosen unit.

State your normal and exceptional duty separately. Ask for the selected cooling arrangement, continuous rating, fan/controller package, alarm contacts and the conditions under which any overload provision is offered. Include the room's actual ventilation and ambient conditions; an indoor label alone does not define the installation.

Source notes: [D1]

03

Request a loss schedule that can be compared

The reviewed series record has no numerical no-load/load-loss schedule for an identified model and capacity. Do not infer loss values from the SCB12/14/18 suffixes, a general energy-saving statement or another manufacturer's table. Ask for the selected unit's guaranteed no-load loss, load loss and reference temperature.

The retained technical table names standards for energy efficiency and dry-type transformers, but citing those documents is not proof that a supplied unit has been independently tested. Ask for the applicable edition and destination requirements, then obtain the reports required for the actual configuration and supplying entity.

  1. Agree the comparison condition

    Fix capacity, voltage, frequency, taps, connection and cooling, then name the loss reference conditions.

  2. Obtain the guarantee

    Request numerical guarantees and tolerances in the returned schedule instead of a series-wide efficiency adjective.

  3. Match the evidence

    Specify the test/report scope, unit identification and any witnessing needed before shipment.

Check whether the report covers the proposed unit →

Source notes: [D2]

04

Compare the complete indoor supply package

Start the purchasing comparison with a shared scope: transformer rating, enclosure, fans, temperature control, terminals, test documents, packing and destination. Ask for final drawings and installation instructions so the electrical and building teams can review the same package before order release.

The product page does not establish a current price range or delivery period. Request an itemized quotation with currency, quantity, validity and a named trade term. Identify whether freight, taxes, installation and commissioning are excluded rather than assuming a headline equipment price covers them.

Separate engineering approval from manufacturing and shipment. Ask the bidder to state the lead-time start event and to give dates for approved drawings, agreed testing, dispatch and arrival. If the offer changes from the quoted 10/0.4 kV duty to a non-standard ratio, request a revised technical return and schedule.

Read the separate 20 kV series and its option boundaries →

Source notes: [D1] [D2]

RFQ

Prepare one 10/0.4 kV configuration

Use this checklist to replace the broad series range with a project definition that suppliers can quote against.

0 of 6 items prepared

Copy and complete this RFQ

Replace the brackets with your project information. This preparation tool stays in your browser; it does not submit an enquiry.

Q&A

Buyer questions

Does 4–10% identify the impedance of the transformer I will receive?

No. It is a published series range. Obtain the selected rating's impedance and its reference conditions on the proposal.

Is the advertised 150% loading a continuous guarantee?

That conclusion is not supported by the reviewed overview. Ask for the chosen model's cooling, duration, ambient and temperature-rise conditions.

Can I derive losses from the SCB model suffix?

No. Request the selected configuration's numerical no-load and load-loss guarantees with their test/reference basis.

Does the manufacturer image show the quoted enclosure and accessories?

It illustrates the listed series. The offered equipment package must be established through the proposal, drawings and scope list.

NOTES

Sources and research scope

The overview was reread on 14 October 2026; technical options are cross-checked against the retained original table and the available page parser. Overview claims, series options and proposed acceptance steps are separated. Price, delivery, model-specific losses and independent tests remain matters for a matched proposal.

View 2 research records
[D1] Daqo SCB 10 kV original product overview

Cast-resin series identity, feature descriptions and forced-air 150% load wording. These are manufacturer statements, not project-specific guarantees.

2026-10-14 · Manufacturer overview read in browser; some page assets load slowly
[D2] Daqo SCB 10 kV technical-parameter record

Indoor installation, SCB12/14/18, 30–5,000 kVA, 10/0.4 kV, impedance and connection/insulation options. Current browser overview did not fully expose the table; no delivered-unit report was obtained.

2026-10-08 · Retained original-page technical table; web parser also returns the table on 2026-10-14

Source references and archived material are retained in the editorial record. Report a correction or provide a current datasheet →