Shandong Dachi Electric Co., Ltd.

Oil-immersed and dry-type transformer routes, with model-specific certification records for a more precise inquiry.

Discuss your project

Shandong Dachi Electric Co., Ltd. is a transformer manufacturer whose published contact location is Dongjiao Industrial Park in Chengwu County, Heze, Shandong. Its catalogue spans distribution transformers, higher-voltage oil-immersed equipment and integrated substation arrangements. The most concrete independent documents found for this profile are CQC entries identifying the company and specific S22-M, SC18 and SCB18 model groups. Those entries make it possible to ask about a defined configuration rather than rely on a broad company-level efficiency claim.

Chinese entity
山东达驰电气有限公司
Contact location
Chengwu County, Heze, Shandong
Company identifier
91371700720758629B
Catalogue routes
Oil-immersed, dry-type and integrated substations
Document anchor
CQC model-group bulletin; February 2025
01

Identify the Chengwu manufacturer on your quotation

Dachi's English contact page names Shandong Dachi Electric Co., Ltd., gives the Chengwu industrial-park address and separates product-sales and after-sales contact channels. The site's footer publishes the Chinese entity's unified social credit code, 91371700720758629B. Use that identifier and the Chinese name 山东达驰电气有限公司 when matching a quotation, invoice or technical agreement to the manufacturing entity.

The catalogue covers standalone transformers and larger equipment packages. At the quotation stage, identify which equipment is supplied by this legal entity and which interfaces belong to another contractor. A transformer order and a complete substation order need different scope schedules even when the same manufacturer can discuss both.

References: [2]

02

Separate transformer families from integrated equipment

The published English product catalogue distinguishes 10 kV and 35 kV dry-type and oil-filled routes, then lists 110 kV, 220 kV and 500 kV oil-immersed categories. It also has separate entries for a mobile substation, split-winding equipment, traction transformers and inverter/energy-storage booster packages. These headings are useful starting points for an inquiry; they are not an all-combinations rating schedule.

Dachi's company introduction describes a wider portfolio envelope up to 750 kV, while the browsed English product grid has categories through 500 kV. Keep those two levels of information separate: ask for the actual proposed design and applicable reference instead of treating a company-wide statement as a guaranteed rating for every route.

Scroll sideways to compare all columns.

Catalogue routeWhat to define in the inquiry
10 kV or 35 kV dry-typeActual voltage ratio, continuous kVA, insulation system, enclosure and cooling arrangement
Oil-immersed distributionRated capacity, tap arrangement, fluid, guaranteed losses and installation constraints
110 kV, 220 kV or 500 kV power transformerSystem voltage, winding arrangement, insulation levels, regulation and site transport limits
Mobile or pre-assembled substationTransformer plus switchgear, protection, metering and enclosure boundaries
Traction or inverter/booster packageSupply and converter interfaces, operating duty and the responsible equipment integrator

References: [1] [3]

03

Use the CQC model groups as document anchors

A CQC bulletin hosted under its February 2025 publication directory names 山东达驰电气有限公司 as the manufacturer. On page 40, it lists the following groups. The recorded effective date is 21 February 2025, with a stated valid-until date of 20 February 2028. This is a reading of that dated bulletin; confirm the current certificate status and coverage when reviewing an offer.

The suffix /10 and listed capacity labels identify the published model groups. Do not fill in an unlisted intermediate model or transfer a certificate from one group to another. The same page does not publish numerical no-load or load losses for these groups, so this profile does not invent a kW comparison from the NX1 designation.

For an offer using one of these names, ask for the complete current certificate and the technical schedule for the exact configuration. Match the manufacturer, model, insulation class and scope before using the document in procurement approval. A named product document is more useful than a general certification badge covering the entire factory.

Scroll sideways to compare all columns.

Certificate number in the bulletinExplicit model groupAdditional scope stated
CQC22701350580S22-M-160/10-NX1, 200/10, 250/10, 315/10, 400/10 and 500/10 variantsAlso shown with corresponding S-M model aliases
CQC22701350578SC18-30/10-NX1, 50/10, 80/10, 100/10, 125/10 and 160/10 variantsF-class insulation; corresponding SC aliases
CQC22701350575SCB18-630/10-NX1, 800/10, 1000/10 and 1250/10 variantsF-class insulation; corresponding SCB aliases

References: [4]

04

Manufacturing questions tied to the stated production routes

Dachi's own introduction describes a technical-standardisation function, a technology centre, a test station and a pilot plant. It also names a GEORG cross-cutting line, epoxy-resin vacuum casting and plasma cutting among its production equipment. These manufacturer statements give a practical starting point for a factory discussion: core preparation and liquid-filled assembly belong to a different manufacturing route from resin-cast windings.

For dry-type equipment, ask how the selected insulation system, casting process and temperature class are connected to the proposed design. For oil-filled equipment, ask for the core and winding assembly plan, insulation drying, tank and fluid preparation, and the production tests included in the purchase specification. Request records for the offered design and delivered units, rather than infer a test result from the presence of a machine or laboratory.

The introduction's capacity, patent and customer totals are not used here as order lead times or project guarantees. Delivery needs a quotation-specific production slot, drawing-approval schedule and test plan. A factory visit can then focus on the relevant process and documents for the selected equipment.

References: [1]

05

Prepare a transformer or package inquiry with clear interfaces

For a standalone transformer, send the rated kVA or MVA, primary and secondary voltages, frequency, vector group, taps, impedance, winding preference and installation conditions. Request guaranteed no-load and load losses with their reference conditions. State any witnessed tests and the document package needed at delivery.

For Dachi's mobile-substation or inverter/booster routes, add the single-line diagram and a responsibility schedule. Specify who supplies switchgear, protection, converter equipment, metering, auxiliary power and controls. Identify transport dimensions, access restrictions and commissioning interfaces before comparing a packaged price with a transformer-only offer.

If certificate coverage matters to the project, put the required model and current certificate verification on the same technical-review checklist. Keep the manufacturer identity, rating schedule, drawing revision and supporting documents together so a substituted configuration can be assessed before approval.

References: [2] [3] [4]

A project brief the factory can respond to

Use this list to prepare your requirements. Checking an item only marks your preparation on this page.

0 of 5 items prepared

Prepare an RFQ for Shandong Dachi Electric Co., Ltd.

Questions buyers ask

Does the CQC bulletin cover every Dachi transformer?

No. The cited entries identify particular model groups. Check the current certificate and its scope for the exact product being offered.

Can I compare losses using the NX1 model name alone?

No. Obtain the guaranteed kW values and reference conditions for the proposed rating. The cited bulletin entries do not supply those loss values.

Should I request a transformer or a complete substation package?

Dachi lists both routes. Describe the equipment boundary explicitly: transformer-only supply, a pre-assembled/mobile substation, or an integrated inverter/booster arrangement require different interface schedules.

Research behind this profile

View 4 research references · reviewed 2026-10-09

Prepared by PowerTransformerB2B. Reviewed 2026-10-09. The sources below identify the published company information and any dated public records used for this profile. Procurement guidance is the platform’s interpretation of those facts.

Company catalogues describe product families and options. Regulatory and exchange records apply to their named entity, date and scope; they do not replace model-specific acceptance documents.

  1. [1] Company introduction and manufacturing routesShandong Dachi Electric · Manufacturer original · reviewed 2026-10-09
  2. [2] Chengwu contact address and legal identifierShandong Dachi Electric · Manufacturer original · reviewed 2026-10-09
  3. [3] English transformer and integrated-equipment catalogueShandong Dachi Electric · Manufacturer original · reviewed 2026-10-09
  4. [4] CQC February 2025 certificate bulletin, page 40China Quality Certification Centre · Certification body original bulletin · reviewed 2026-10-09