Request a quotation

POWER TRANSFORMER SOURCING

Tianrui SCBH15 amorphous-core dry-type series

Model specifications, source documentation and manufacturer contact.

Series reference · amorphous-core resin-cast dry-type

Tianrui’s SCBH15 family combines an amorphous-alloy core with resin-cast dry-type construction. Its original page lists 6/10 kV variants, 50 Hz and 30–3,150 kVA, while describing a copper-foil low-voltage winding. The core-related energy claim is not a capacity-specific loss guarantee or proof of a project saving.

Discuss this configuration Jiangsu Tianrui Transformer logoJiangsu Tianrui Transformer →

CATALOGUE IDENTITY

SCBH15
Capacity range
30–3,150 kVA
Voltage / frequency
6 or 10 kV; 50 Hz
Core family
Amorphous alloy
LV winding description
Copper foil; full winding schedule still required
01

Read the core and winding descriptions separately

The manufacturer describes either a three-phase five-column or three-column core arrangement, with supporting frame protection. These are series construction choices. Obtain the selected core arrangement and handling instructions for the proposed rating instead of assuming both are present in one design.

The low-voltage coil is explicitly described as copper foil. That statement does not establish the high-voltage conductor material, a complete bill of materials or one universal winding construction for every variant. Ask for both winding materials, insulation system and temperature-rise limits on the returned specification.

The model-meaning illustration identifies SCBH15 as three-phase, resin-cast, low-voltage foil and amorphous alloy. Its blank capacity and rated-high-voltage positions reinforce that an exact model must be specified. The code describes a family; it does not supply the missing selected-unit loss, mass or dimension schedule.

Source notes: [P1]

02

Select one compatible electrical arrangement

The technical list gives 6 and 10 kV voltage levels, frequency 50 Hz, capacity 30–3,150 kVA, Dyn11/Yyn0, F/H insulation and tap choices ±2 × 2.5% or ±5%. It also lists de-energized or on-load regulation. These are options without a full configuration mapping, not permission to combine every choice freely.

The high-voltage insulation entries are 6 kV LI60AC20 and 10 kV LI75AC35. Request the complete dielectric schedule for all windings and the chosen ratio; the reviewed list does not fix a secondary voltage or an enclosure/cooling package. Confirm which tap and regulation arrangement the offered model actually supports.

Scroll this table to read every column →

ItemPublished referenceBuyer action
Capacity / frequency30–3,150 kVA / 50 HzSelect one capacity and confirm destination supply frequency.
HV insulation6 kV LI60AC20; 10 kV LI75AC35Ask for the complete selected-unit winding schedule.
Connection / insulation classDyn11 or Yyn0; F or HConfirm one matched design and thermal limit.
Taps / regulation±2 × 2.5% or ±5%; de-energized or on-loadRequest the exact tap apparatus, range and operation scope.

Source notes: [P1]

03

Ask for losses and test conditions, not a blanket saving

The source claims no-load loss 70–80% below a stated GB/T10228 reference value. It does not identify a standard edition, selected capacity’s comparison value or current guaranteed loss schedule in the reviewed description. Treat this as a manufacturer comparative claim, not a verified percentage for the unit you intend to buy.

Ask for no-load and load-loss guarantees, the load-loss reference temperature, measurement basis and agreed tolerances for the chosen configuration. A low no-load claim alone does not establish total annual energy cost. Compare at the same duty and supply operating hours, load profile and energy-price assumptions for a project study.

The source also makes a low-partial-discharge claim in a translated manufacturing description. Request the numerical requirement in an unambiguous unit, test voltage, method and matched report. Its process wording and qualitative short-circuit statement do not substitute for a verified test schedule for the ordered design.

  1. Identify the baseline

    Ask the supplier to state the standard edition, model/rating and comparison conditions behind any percentage claim.

  2. Obtain exact guarantees

    Keep measured results, contractual guarantees and general series claims in separate fields.

  3. Evaluate the project duty

    Compare equal configurations and the actual loading; leave savings unknown where inputs or evidence are missing.

Source notes: [P1]

04

Specify the installation and commercial handover

The application list includes buildings, networks, stations and power facilities but does not provide site-specific suitability. Give ambient, altitude, ventilation, enclosure, terminals and service-access requirements. Obtain the final layout, installed/transport mass, cooling/controller package and installation instructions for the selected design.

No verified price or lead time is available. Ask for a dated, itemized offer covering the selected core/winding design, regulation apparatus, cooling, enclosure, tests, packing and support. Confirm currency, trade term and validity. Track technical approval, manufacture, tests, factory release, dispatch and destination arrival separately, identifying the event starting the quoted lead time.

Source notes: [P1]

RFQ

Prepare a configuration-specific inquiry

Select one capacity, 6/10 kV variant and actual secondary voltage.

0 of 6 items prepared

Copy and complete this RFQ

Replace the brackets with your project information. This preparation tool stays in your browser; it does not submit an enquiry.

Q&A

Buyer questions

Does copper foil mean both windings are copper?

The text identifies the low-voltage copper-foil winding only. Confirm high-voltage materials separately.

Is 70–80% my guaranteed annual saving?

No. It is a manufacturer no-load comparison claim without a complete matched baseline here; annual savings need the selected values and duty.

Is the tap changer definitely on-load?

Both regulation modes are listed as family options. Obtain the exact offered apparatus and configuration.

Is the secondary voltage fixed by this page?

The technical list does not establish one selected secondary ratio. State it in the inquiry and obtain confirmation.

NOTES

Sources and research scope

Manufacturer material reviewed on 14 October 2026. Published facts and buyer recommendations are distinguished in the sections above. No verified current price, lead time or independent unit test was established.

View 1 research records
[P1] Jiangsu Tianrui Transformer manufacturer product reference

Original SCBH15 overview, technical list and model-meaning image. LV copper scope, voltage/frequency/range and option boundaries checked; percentage and partial-discharge claims not adopted as selected-unit guarantees.

2026-10-14 · Original browser text and manufacturer model-meaning illustration read

Source references and archived material are retained in the editorial record. Report a correction or provide a current datasheet →